common: Fix WMI exception (#1422)
* common: Fix WMI exception We currently don't check if WMI service is available when we get the CPU name and the RAM size. This fix the issue by catching all exceptions and set default values instead. Close #1353 * remove useless assign * Fix Exception * Address comments Co-authored-by: Thog <me@thog.eu>
This commit is contained in:
parent
9878fc2d3c
commit
16bab8fb88
1 changed files with 27 additions and 4 deletions
|
@ -1,4 +1,7 @@
|
||||||
|
using Ryujinx.Common.Logging;
|
||||||
|
using System;
|
||||||
using System.Management;
|
using System.Management;
|
||||||
|
using System.Runtime.InteropServices;
|
||||||
|
|
||||||
namespace Ryujinx.Common.SystemInfo
|
namespace Ryujinx.Common.SystemInfo
|
||||||
{
|
{
|
||||||
|
@ -9,14 +12,34 @@ namespace Ryujinx.Common.SystemInfo
|
||||||
|
|
||||||
public WindowsSysteminfo()
|
public WindowsSysteminfo()
|
||||||
{
|
{
|
||||||
foreach (ManagementBaseObject mObject in new ManagementObjectSearcher("root\\CIMV2", "SELECT * FROM Win32_Processor").Get())
|
bool wmiNotAvailable = false;
|
||||||
|
|
||||||
|
try
|
||||||
{
|
{
|
||||||
CpuName = mObject["Name"].ToString();
|
foreach (ManagementBaseObject mObject in new ManagementObjectSearcher("root\\CIMV2", "SELECT * FROM Win32_Processor").Get())
|
||||||
|
{
|
||||||
|
CpuName = mObject["Name"].ToString();
|
||||||
|
}
|
||||||
|
|
||||||
|
foreach (ManagementBaseObject mObject in new ManagementObjectSearcher("root\\CIMV2", "SELECT * FROM Win32_OperatingSystem").Get())
|
||||||
|
{
|
||||||
|
RamSize = ulong.Parse(mObject["TotalVisibleMemorySize"].ToString()) * 1024;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
catch (PlatformNotSupportedException)
|
||||||
|
{
|
||||||
|
wmiNotAvailable = true;
|
||||||
|
}
|
||||||
|
catch (COMException)
|
||||||
|
{
|
||||||
|
wmiNotAvailable = true;
|
||||||
}
|
}
|
||||||
|
|
||||||
foreach (ManagementBaseObject mObject in new ManagementObjectSearcher("root\\CIMV2", "SELECT * FROM Win32_OperatingSystem").Get())
|
if (wmiNotAvailable)
|
||||||
{
|
{
|
||||||
RamSize = ulong.Parse(mObject["TotalVisibleMemorySize"].ToString()) * 1024;
|
Logger.PrintError(LogClass.Application, "WMI isn't available, system informations will use default values.");
|
||||||
|
|
||||||
|
CpuName = "Unknown";
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
Reference in a new issue